![]() Always verify range with a FG-701 Glassbreak Simulator. NOTE: Ranges are approximate and vary with each room’s acoustic properties. SENS1 & SENS2 configure sensitivity SENSITIVITY MAX MEDIUM LOW LOWEST APPROXIMATE RANGE 7.6m (25 ft) 4.6m (15 ft) 3m (10 ft) 1.5m (5 ft) SENS1 OFF ON OFF ON SENS2 OFF OFF ON ON A rib in the screw cavity lightly holds the screw in place when installing the detectorĮnter Test Mode using FG-701 (see Testing the Detector on the next page) or manually by shorting the Test Mode pads (as below). * The screw retention feature simplifies installation. * 3.5mm (#6) screws work best with the screw retention feature. screw head size 4.2mm or 4.8mm Ĭonnect detector using 18 to 22 AWG wire, with ends stripped approximately 6mm (1/4 in.) Use the appropriate wiring method as shown in these diagrams: Mount detector using appropriate hardware.ĩ.7mm Max. Place unit over wall tamper screw, if used! Use mounting holes as template to mark ceiling or wall.Set screw depth to make contact w/ bottom of tamper cavity when device is installed Remove plastic tab from rear of detector.Tamper Switch Mounting Hole Microphone Terminal Block Refer to Supplemental Information (next page) for complete descriptions of these installation steps FG-1625/FG-1625T Glassbreak Detector FlexGuard® FG-1625/FG-1625T Glassbreak Detector Installation Instructions